(Summary description)Communication failure: the controller cannot recognize the sensor, first check whether the connection cable is correct, if it is a MOBA controller, then check the number of sensors set, Siming main controller automatically recognizes the balance beam mode and single boot sensor mode, but the single The road mode and wire mode of the boot sensor need to be switched. Then exchange instruments to determine the fault.

General faults and emergency treatment of balance beams

(Summary description)Communication failure: the controller cannot recognize the sensor, first check whether the connection cable is correct, if it is a MOBA controller, then check the number of sensors set, Siming main controller automatically recognizes the balance beam mode and single boot sensor mode, but the single The road mode and wire mode of the boot sensor need to be switched. Then exchange instruments to determine the fault.

Information

  1.通讯故障:控制器识别不了传感器,首先检查连接电缆是否正确,如果是MOBA的控制器其次检查设定的传感器个数,四明主控器自动识别平衡梁模式和单长靴传感器模式,但是单长靴传感器的路面模式与钢丝模式是需要切换的。然后进行互换仪器确定故障。

  2.控制器在手动或者自动状态下上下不动,请检查摊铺机上面的自动是否打开,其次检查主机连接电缆是否连接到位,而后再检查主控器的输出方式是否正确,还有些摊铺机需要摊铺模式走动后才有动作(如DYNAPAC、VOLVO和三一部分机型)。最后再调整仪器和电缆确定故障。

  3.连接上仪器后摊铺机找平油缸只往一个方向动作一直走到头,首先检查连接电缆,而后检查主控器。

  4.如果遇到单个传感器不能工作时可以去掉中间一个传感器应急工作。

  5.遇到其他故障时可以用替换法逐个排除故障点。